IPC@CHIP® RTOS-PPC – API Documentation

Header image

Main page


CHIP.INI [DEVICE]


[DEVICE]
NAME=Define the name of this device

This name will show up with the 'Chiptool' software when the network is scanned.

Maximum name size: 20 characters
Default:
No default.
Example:
 [DEVICE]
 NAME=MyChip
Since:
SC2x3 V1.00


[DEVICE]
FILESHARING=0/1

Disable (0) / Enable (1) the file sharing option.
Default:
By default the filesharing option is disabled.
Example:
 [DEVICE]
 FILESHARING=1

See also:

Since:
SC2x3 V1.00


[DEVICE]
POWERSAVE=0/1/2/3/4

Five modes of power control are selectable from the CHIP.INI. Mode 1 is the default mode.

  • 0 - No power saving. All devices are left operating at full power. This option provides no performance improvement over the default mode 1. It is offered only to allow users to make worst case power measurements during development.
  • 1 - Enable dynamic power management.
  • 2 - Enter DOZE mode when ever system is idle.
  • 3 - Enter NAP mode when ever system is idle.
  • 4 - Enter SLEEP mode when ever system is idle.

Go here for a more detailed description of these power save modes.

See also BIOS_Power_Save() API.

Default:
Mode 1 = Dynamic power management
Example:
 [DEVICE]
 POWERSAVE=2
Since:
SC2x3 V1.02


[DEVICE]
SAFEMODE=0/1

Disable (0) / Enable (1) the CHIP.INI safe mode. If the safe mode is disabled, then all internal services, like FTP server, Web server, Telnet server, UDP config server, SSH server etc. are enabled with default settings. This allows an easy startup with the IPC@CHIP®. Services must be disabled explicitly.

If the user enables the safe mode setting, all internal services are disabled per default. Services must be enabled explicitly. This mode is useful when preparing for a release. It also assures that after an update to a future RTOS release, all possible new services that this release implements are disabled per default.
Default:
Safe mode is disabled per default.
Example:
 [DEVICE]
 SAFEMODE=1
Since:
SC2x3 V1.00





Top of page | Main page

Copyright © 2017 Beck IPC GmbH
Generated on Thu Jan 26 16:21:35 2017 by Doxygen 1.6.1