IPC@CHIP Modbus library – API Documentation

Header image

Main page


int mbTCP_cl_wr_regs_packed ( MbHandle  handle,
u8  unitId,
u16  startAddress,
u16  quantity,
u8 registerData,
u8 exception,
u32  timeoutMs,
int *  errorCode 
)

Same as mbTCP_cl_wr_regs() but expects registerData in a packed manner.

Parameters:
[in] handle : Handle returned by mbTCP_cl_init()
[in] unitId : Unit identifier
[in] startAddress : Address of first register to write
[in] quantity : Number of registers to write
[in] registerData : User provided storage, contains register values Need not to be aligned (i.e. packed)
[in] timeoutMs : Wait max. timeout in [ms] for a reply.
[out] exception : Exception code (see ModbusExceptionCodes).
[out] errorCode : Socket API error code
Returns:
0 : Execution successful, check *exception for possible exception code.
-1 : Timeout, no reply received
-2 : Received garbage (invalid Modbus frame data)
-5 : TCP socket fault, see errorCode
Since:
V1.01





Top of page | Main page

Copyright © 2017 Beck IPC GmbH
Generated on Thu Mar 9 18:00:33 2017 by Doxygen 1.6.1